Xiang Welding Industrial Co Ltd
Higher deoxidization elements allow this metal cored wire to have more tolerance for mill scale welding applications
Description
Welding Positions
Flux Cored Welding Wire
Classification:
A5.18: E70C-6M H4
EN ISO 17632-A: T46 2 M M21 3 H5
TYPICAL DIFFUSIBLE HYDROGEN*
Gas-shielded, metal-powder, metal-cored wire



75-95% Argon (Ar)/Balance Carbon Dioxide (CO2), 95% Argon (Ar)/5% Oxygen (O2),35-50 cfh (17-24 /min)



Direct Current Electrode Positive (DCEP)


0.035”(0.9 mm), 0.045”(1.2 mm), 0.052”(1.4 mm), 1/16”(1.6 mm), 5/64" (2.0 mm), 3/32" (2.4 mm)



Not recommended



Product should be stored in a dry, enclosed environment, and in its original intact packaging
Single and multiple pass applications with Argon/CO2 shielding gas
●Single and multi-pass welding
●Automatic and mechanized welding
●Non-alloyed and fine grain steels
●Storage vessels
●Steel structures
●Earthmoving equipment
●Rail cars
APPLICATIONS
WIRE TYPE
SHIELDING GAS
TYPE OF CURRENT
STANDARD DIAMETERS
RE-DRYING
TYPICAL WELD METAL CHEMISTRY* (Chem Pad)
TYPICAL MECHANICAL PROPERTIES* (As Welded)
CONFORMANCES AND APPROVALS:
●AWS A5.18, E70C-6M H4
●AWS A5.18M, E48C-6M H4
●ASME SFA 5.18 E70C-6M H4
●ABS, 80% Ar/20% CO2, 3YSA (0.035”- 1/16" diameter electrodes)
●Bureau Veritas, 80% Ar/20% CO2, S3YMH5 (0.035" - 1/16" diameter electrodes)
●CE Marked per CPR 305/2011
●CWB, 75-95% Ar/Balance CO2, E491C -6MJ-H4 (0.9 mm - 1.6 mm diameter electrodes)
●CWB, 95% Ar/5% O2, E491C-6MJ-H4 (1.2 mm - 1.6 mm diameter electrodes)
●CWB, E491T15-(M12A4, M20A4, M21A4, M22A4, GA4)-CS 1-H4, (E491C-6MJ-H4) (1.2- 1.6 diameter electrodes)
●DNV-GL, 80% Ar/20% CO2, II Y40MS(H5)
●ENISO17632-A:T462MM213H5
●CE Marked per CPR 305/2011 (1.2 mm - 1.6 mm diameter electrodes)
●Lloyd's Register, 80% Ar/20% CO2, 3Y40S H5
●AWS D1.8/D1.8M, 75% Ar/25% CO2, [0.045" (1.2 mm), 1/16" (1.6 mm) diameter electrode]
●AWS D1.8/D1.8M, 85% Ar/15% CO2, [0.052”(1.4 mm), 1/16" (1.6 mm) diameter electrode]
●Maintaining a proper welding procedure - including pre-heat and interpass temperatures - may be critical
depending on the type and thickness of steel being welded.
●For out of position welding, short circuit or pulsed spray transfer mode must be used.
●Pulse waveforms are designed with nominal operating points that may result in average voltage and current values that differ from the above table. Generally, pulse processes can be expected to produce lower heat inputs than a standard CV process.
●See Above: This information was determined by welding using 90% Ar/10% CO2 shielding gas with a flow rate between 35-50 cfh (17-24 l/min). For the higher CO2 shielding gas mixtures within the recommended range, increase listed voltages by 1-3 volts.
STORAGE
FEATURES AND BENEFITS
●High deposition rates and efficiencies
●Virtually no slag coverage
●Outstanding high-production performance
●Smooth arc characteristics
●Low diffusible hydrogen weld deposit
●Low smoke and spatter levels
●Excellent for both CV and pulsed welding
●Improves productivity compared to solid wire or flux-cored electrodes
●Reduces clean-up time, improves productivity
●Excellent for robotic welding
●Improved operator appeal, assists in maintaining consistent weld quality
●Minimizes risk of hydrogen-induced cracking
●Improves operator appeal and productivity
●Promotes versatility in procedure development
Keywords
AWS A5.18: E70C-6M H4,Gas-Shielded Wires, Carbon Steel,Flux Cored Welding Wire ,China, Tianjin.
EN ISO 17632-A: T46 2 M M21 3 H5
STANDARD DIAMETERS AND PACKAGES: 
For a complete list of diameters and packaging, please contact Hobart
TYPICAL CHARPY V-NOTCH IMPACT VALUES* (As Welded)