Xiang Welding Industrial Co Ltd
Single and multiple pass welding with recommended submerged arc fluxes, high-strength low-alloy steels, structural components, heavy equipment components, ship panels, wind towers
• Structural & bridge fabrication
• Wind tower
• Power transmission poles
• Heavy equipment
• Shipbuilding
• ~80 KSI (550 MPa) HSLA steels
• Weathering Steel
Main Application
RE-DRYING
CONFORMANCES AND APPROVALS
TYPICAL WELD DEPOSIT CHEMICAL COMPOSITION*
Classification:
AWS A5.23: ECM1
Related Products:SWX 120, SWX 150, HA-495 Sub-Arc Flux, HN-590 Sub-Arc Flux
For a complete list of diameters and packaging, please contact Hobart Brothers at
(800) 424-1543 or (937) 332-5188 for International Customer Service.
Description
AWS A5.23: ECM1,Submerged Arc Cored Wires Low-Alloy Steel,China, Tianjin
Category
is a low-alloy composite metal-cored wire electrode for submerged arc welding in high strength applications.And it meets AWS A5.23 chemistry M1, and is designed for tensile strength levels above 80 ksi.
FEATURES&BENEFITS
Not recommended
Industries
Structural & bridge fabrication, heavy equipment, power generation, shipbuilding, offshore
RECOMMENDED FLUXES
• Metal-cored wire can offer improved deposition rates compared to solid wires at comparable amperages
• Metal-cored wires offer broader penetration profiles compared to solid wires at comparable welding parameters
• Provides very good low-temperature impact toughness in both the as-welded and stress- relieved conditions
• Weld deposit chemical composition requirements are identical to those of EM1 solid wires
• Suitable for use with a wide variety of fluxes
• Provides potential to increase travel speed for improved productivity
• Helps to prevent burn-through when welding at high currents on root passes and relatively thin materials.
• Helps minimize the risk of cracking in critical applications or harsh service environments
• Suitable as a higher productivity alternative in many applications currently using EM1 (or similar 80 ksi) solid wire
• Provides versatility in procedure development and optimizing the performance of the welding application
WIRE TYPE
 Metal-powder, metal-cored wire
CURRENT
HA-495, HN-590, SWX 120, SWX 150
STANDARD DIAMETERS
Direct Current Electrode Positive (DCEP), Direct Current Electrode Negative (DCEN), Alternating Current (AC)
5/64” (2.0 mm), 3/32” (2.4 mm), 1/8” (3.2 mm), 5/32” (4.0 mm)
STORAGE
Product should be stored in a dry, enclosed environment, and in its original intact packaging
AWS CLASSIFICATIONS
TYPICAL MECHANICAL PROPERTIES*
TYPICAL CHARPY V-NOTCH IMPACT VALUES*
TYPICAL OPERATING PARAMETERS*
Maintaining a proper welding procedure - including pre-heat and interpass temperatures - may be critical depending
on the type and thickness of steel being welded.
Parameters are provided for informational purposes only. All values are approximate. The optimal voltage may vary (typically ±2 volts) depending on the choice of flux, material thickness, joint design, and other variables specific to the application.
Likewise, actual deposition rate may vary depending on choice of flux and contact tip to work distance.
STANDARD PACKAGING
TYPICAL DIFFUSIBLE HYDROGEN* (Gas Chromatography per AWS A4.3)
Welding Positions: