Single and multiple-pass applications welding using recommended submerged arc fluxes, high-strength low-alloy steels, sour gas pipeline, storage tanks, pressure vessels, double jointing, heavy equipment components
• Offshore structures
• Heavy equipment
• Oil & gas
• Pressure vessel
• ~100 KSI HSLA Steels with impact toughness requirements down to -60°C
Main Application
RE-DRYING
Welding Positions:
TYPICAL WELD DEPOSIT CHEMICAL COMPOSITION*
Classification:
AWS A5.23: EF3
Related Products:SWX 120, SWX 150, SWX 160, HN-590 Sub-Arc Flux
For a complete list of diameters and packaging, please contact Hobart Brothers at (800) 424-1543 or (937) 332-5188 for International Customer Service.
Description
AWS SWX 120, SWX 150, SWX 160, HN-590 Sub-Arc Flux, Submerged Arc Solid Wire Low-Alloy Steel ,China, Tianjin,EN ISO 14174: S3Ni1Mo
Category
AWS A5.23: EF3 is a copper-coated, low-alloy, solid wire for submerged arc welding. The nominal nickel-molybdenum composition of SDX S3Ni1Mo-EF3 provides good low-temperature toughness and is suitable for welding many high-strength low-alloy (HSLA) . In an effort to best serve the packaging needs and requirements of our customers globally, this product features region-exclusive part numbers. To obtain the complete list of part numbers available in your region, e-mail us at subarc@itw-welding.com, contact your regional ITW Welding office, or contact Hobart Brothers customer service (North America)
FEATURES&BENEFITS
Not recommended
Industries
Structural fabrication, oil &gas, power generation, heavy equipment
RECOMMENDED FLUXES
• Copper-coated wire
• Nominal 1%Ni/0.5% Mo composition
• Provides good low-temperature impact toughness
• Offers optimal consistency in electrode feeding and electrical transfer
• Suitable for welding a wide range of ~100 KSI high-strength low-alloy steels
• Helps to minimize risk of cracking in demanding service conditions
WIRE TYPE
Copper-coated solid wire
CURRENT
SWX 120, SWX 150, SWX 160, HN-590
STANDARD DIAMETERS
Direct Current Electrode Positive (DCEP), Direct Current Electrode Negative (DCEN), Alternating Current (AC)
3/32” (2.4 mm), 1/8” (3.2 mm)
STORAGE
Product should be stored in a dry, enclosed environment, and in its original intact packaging
AWS CLASSIFICATIONS
TYPICAL WIRE CHEMICAL COMPOSITION*
TYPICAL MECHANICAL PROPERTIES*
TYPICAL CHARPY V-NOTCH IMPACT VALUES*
TYPICAL OPERATING PARAMETERS*
Maintaining a proper welding procedure - including pre-heat and interpass temperatures - may be critical depending
on the type and thickness of steel being welded.
Parameters are provided for informational purposes only. All values are approximate. The optimal voltage may vary (typically ±2 volts) depending on the choice of flux, material thickness, joint design, and other variables specific to the application.
Likewise, actual deposition rate may vary depending on choice of flux and contact tip to work distance.
STANDARD PACKAGING
EN ISO CLASSIFICATIONS