Designed as a low Manganese (Mn) E71T-1C product to assist with conformance to OSHA requirements and NIOSH and ACGIH recommendations for Manganese. This product offers reductions of Mn in the weld fume of 60-80% over a standard E71T-1C product with low diffusible hydrogen as well as enhanced operator appeal and excellent out of positional capability.
Description
Welding Positions
Flux Cored Welding Wire
Classification:
AWS A5.20: E71T-1C/-9C/-12C H8
TYPICAL DIFFUSIBLE HYDROGEN*
Fast freezing, rutile type, flux-cored wire
100% Carbon Dioxide(CO2) 35-50 cfh(14-24 //min) TYPE OF
Direct Current Electrode Positive (DCEP)
0.045”(1.2mm),0.052"(1.4mm),1/16"(1.6 mm)
Not recommended
Product should be stored in a dry,enclosed environment,and in its original intact packaging.
Excellent for applications where compliance with OSHA regulations, or NISOH and ACGIH recommendations for Manganese could be a concern, such as confined spaces or high volume manufacturing.
APPLICATIONS
SLAG SYSTEM OR WIRE TYPE
SHIELDING GAS
TYPE OF CURRENT
STANDARD DIAMETERS
RE-DRYING
TYPICAL WELD METAL CHEMISTRY* (Chem Pad)
TYPICAL MECHANICAL PROPERTIES*
CONFORMANCES AND APPROVALS
• AWS A5.20, E71T-1C H8, E71T-9C H8, E71T-12C H8
• AWS A5.20M, E491T-1C H8, E491T-9C H8, E491T-12C H8
• ASME SFA 5.20, E71T-1C H8, E71T-9C H8, E71T-12C H8
• ABS, 100% cO,, 2YSA H10
• CWB, 100% CO2, E491T1-C1A3-CS2-H8 (E491T-12-H8)
STANDARD DIAMETERS AND PACKAGES:
For a complete list of diameters and packaging, please contact
•Maintaining a proper welding procedure · including pre-heat and interpass temperatures · may be critical depending on the type and thickness of steel being welded.
•See Above: The information above was determined by welding using 100% CO2 shielding gas with a flow rate between 35- -50 cfh (14- ·24 l/min).
•All positions include: Flat, Horizontal, Vertical Up, and Overhead.
STORAGE
FEATURES AND BENEFITS
•Enhanced out of positional capability
•Low spatter and fume
•Extremely low manganese emissions
•Enhanced slag release
•Increased operator appeal
•Improved operator comfort and productivity
•Assists with conformance to environmental regulations
•Reduced clean-up time and risk of inclusions
TYPICAL CHARPY V-NOTCH IMPACT VALUES*