Xiang Welding Industrial Co Ltd
Formulated to allow excellent mechanical toughness properties at lower temperatures in both the as welded and post weld heat treat conditions. All position wire with low hydrogen levels.
Description
Welding Positions
Flux Cored Welding Wire
Classification:
AWS A5.20: E71T-1MJ H4, E71T-9MJ H4, E71T-12MJ H4
EN ISO 17632-AT42 6P M21 2 H5
TYPICAL DIFFUSIBLE HYDROGEN*
Fast-freezing, rutile-type, flux-cored wire



75-80% Argon (Ar)/Balance Carbon Dioxide (CO,), 35-50 cfh (17-24 l/min)


Direct Current Electrode Positive (DCEP)


0.045" (1.2 mm), 0.052" (1.4 mm)



Not recommended



Product should be stored in a dry, enclosed environment and in its original intact packaging
· Non-alloyed and fine grain steels
· Single or multi-pass welding
· Offshore drilling rigs
· Jackup rig fabrication
· Transmission and process piping
· Shipbuilding
APPLICATIONS
SLAG SYSTEM OR WIRE TYPE
SHIELDING GAS
TYPE OF CURRENT
STANDARD DIAMETERS
RE-DRYING
TYPICAL WELD METAL CHEMISTRY* (Chem Pad)
TYPICAL MECHANICAL PROPERTIES*
CONFORMANCES AND APPROVALS
· AWS A5.20, E71T-1MJ H4, E71T-9MJ H4, E71T-12MJ H4
· AWS A5.20M, E491T-1MJ H4, E491T-9MJ H4, E491T-12MJ H4
· ASME SFA 5.20, E71T-1MJ H4, E71T-9MJ H4, E71T-12MJ H4
· CWB, 75% Ar/25% CO2, E491T1-M21A4-CS2-H4 (E491T-12MJ-H4)[1 .2 mm- 1 .4 mm diameter electrode]
· EN ISO 17632-A T426P M21 2 H5
· CE Marked per CPR 305/2011
STANDARD DIAMETERS AND PACKAGES: 
For a complete list of diameters and packaging, please contact
· Maintaining a proper welding procedure · including pre-heat and interpass temperatures · may be critical depending on the type and thickness of steel being welded.
· See Above: This information was determined by welding using 75% Ar/25% CO2 shielding gas with a flow rate between 35-50 cfh (17-24 l/min). When welding using 80% Ar/20% CO2 shielding gas, reduce voltage up to one volt.
· All positions include: Flat, Horizontal, Vertical Up, and Overhead.
STORAGE
FEATURES AND BENEFITS
· Fast freezing slag
· Low diffusible hydrogen
· Low moisture pickup
· Excellent CVN impact toughness
· Maintains CVN toughness after stress relief
· Suitable for all position welding
· Helps minimize risk of hydrogen-induced cracking, can lower preheat requirements in certain applications
· Maintains low diffusible hydrogen following atmospheric exposure
· Resists cracking in severe applications
· Exceeds 20 ft*lbs (27J) CVN impact strength @ -76"F (-60"C) after 10 Hrs of stress relief
TYPICAL CHARPY V-NOTCH IMPACT VALUES*