AWS A5. 20: E71T-1MJ H4 is a rutile flux cored wire for carbon steel applications. Fast freezing slag for higher deposition rates in all position.
Description
Welding Positions
Flux Cored Welding Wire
Classification:
AWS A5. 20: E71T-1MJ H4, E71T-1C H4, E71T-9MJ H4, E71T-9C H4
E71T-12MJ H4, E71T-12C H4
EN 17632-A: T 46 4 P M 1 H5, T 46 2 P C 1 H5
Fast-freezing, rutile-type, flux-cored wire
100% Carbon Dioxide (CO2), 75-80% Argon (Ar)/Balance Carbon Dioxide (CO2),35-50 cfh (17-24 l/min)
Direct Current Electrode Positive (DCEP)
0.045” (1.2 mm), 1/16” (1.6 mm)
Not recommended
Product should be stored in a dry, enclosed environment, and in its original intact packaging.
For Carbon steel applications with mixed gas 75-80% Argon (Ar)/ balance Carbon Dioxide (CO2) and 100 % Carbon Dioxide (CO2)
• Single or multi-pass welding • Non-alloyed and fine grain steel • General fabrication
• Offshore • Heavy equipment • Equipment repairs and modifications
• Pipelines • Pressure vessels • Structural fabrication
APPLICATIONS
SHIELDING GAS
TYPE OF CURRENT
STANDARD DIAMETERS
RE-DRYING
TYPICAL WELD METAL CHEMISTRY* (Chem Pad)
TYPICAL MECHANICAL PROPERTIES*
CONFORMANCES AND APPROVALS
• AWS A5.20, E71T-1MJ H4, E71T-1C H4, E71T-9MJ H4, E71T-9C H4, E71T-12MJ H4, E71T-12C H4
• AWS A5.20M, E491T-1MJ H4, E491T-1C H4, E491T-9MJ H4, E491T-9C H4, E491T-12MJ H4, E491T-12C H4
• ASME SFA 5.20, E71T-1MJ H4, E71T-1C H4, E71T-9MJ H4, E71T-9C H4, E71T-12MJ H4, E71T-12C H4
• ABS, 100% CO2, 3YSA, 3Y400SA H5, 82% Ar/18% CO2, 4YSA, 4Y400SA H5
• CWB, 100% CO2, E491T1-C1A3-CS1-H4 (E491T-9-H4)
• CWB, 80% Ar/20% CO2, E491T1-M21A4-CS1-H4 (E491T-9MJ-H4)
• DNV-GL, 100% CO2, IV Y40MS(H5), 75-80% Ar/Balance CO2 , IV Y40MS(H5)
• EN 17632-A: T 46 4 P M 1 H5, T 46 2 P C 1 H5
• Lloyd’s Register, 100% CO2, 3Y40S H5, 82% Ar/18% CO2, 3Y40S H5
STANDARD DIAMETERS AND PACKAGES:
For a complete list of diameters and packaging, please contact
• Maintaining a proper welding procedure - including pre-heat and interpass temperatures - may be critical
depending on the type and thickness of steel being welded.
• See Above: This information was determined by welding using 75% Argon (Ar)/25% Carbon Dioxide (CO2) shielding
gas with a flow rate between 35-50 cfh (17-24 l/min). When welding using 100% Carbon Dioxide (CO2) shielding gas,increase voltage by approximately 0.5 - 1 volts.
• All positions include: Flat, Horizontal, Vertical Up, and Overhead.
STORAGE
FEATURES AND BENEFITS
●Seamless flux-cored electrode
●Low hydrogen weld deposit
●Fast-freezing slag
●Smooth arc characteristics
●Easy slag removal
●Good impact toughness, especially when used with a Argon-CO2 shielding gas mixture
●Very low moisture reabsorption after extended exposure
●Minimizes risk of hydrogen-induced cracking
●Excellent out-of-position performance
●Assists producing welds of consistent appearance and quality
●Reduces clean-up time, minimizes risk of inclusions
●Minimizes risk of cracking in critical applications
TYPICAL CHARPY V-NOTCH IMPACT VALUES*
INDUSTRIES
Automatic and mechanized welding, Steel Structures
FAST FREEZING
TYPICAL MECHANICAL PROPERTIES*