Xiang Welding Industrial Co Ltd
AWS A5.36 E71T1-C1A4-CS1
(AWS A5.36M E491T1-C1A4-CS1)
(AWS A5.20 E71T-1C/ -9C/ -9C J)
EN ISO 17632-A T 42 4 P C1 1 H10
JIS Z3313 T 49 4 T1-1 C A
Notes on Usage
Welding Positions:
1. Proper preheating(50~150℃, 122~302℉) and interpass temperature
must be used in order to release hydrogen which may cause cracking
in weld metal when electrodes are used for medium and heavy plates
2. Use 100% CO₂gas.
Applications
AWS A5.36 E71T1-C1A4-CS1 Typical industrial applications include shipbuilding, machinery, bridge, structural fabrication and building.
Characteristics on Usage
AWS A5.36 E71T1-C1A4-CS1 is a rutile-type flux cored wire to be used with 100%CO₂
Gas shielding. Provide an exceptionally smooth and stable arc with a fast
freezing slag system, and low spatter levels. Bead shape and appearance are excellent in all position welding.
Mechanical Properties& Chemical Compositions of all-Weld Metal
Welding Conditions
Welding Position : 1G(PA)
Diameter : 1.2mm (0.045in)
Shielding Gas : 100%CO₂
Flow Rate : 20 ℓ /min
Amp./ Volt. : 280A / 32V
Stick-Out : 20~25mm
(0.79~0.98in)
Pre-Heat : R.T .
Interpass Temp. : 150±15℃ (302±59℉)
Polarity : DC(+)