AWS A5.36 E81T1-C1A(P)8-K2
(AWS A5.29 E81T1-K2C)
EN ISO 17632-A T 46 6 1.5Ni P C1 1 H5
Notes on Usage
Welding Positions:
1. Proper preheating(50~150℃) and interpass temperature must
be used in order to release hydrogen which may cause cracking
in weld metal when electrodes are used for medium and heavy
plates
2. Use 100% CO2 gas.
Applications
AWS A5.36 E81T1-C1A(P)8-K2 is a titania type flux cored wire for welding of low-temperature service steel
Characteristics on Usage
AWS A5.36 E81T1-C1A(P)8-K2 is a titania-type flux cored wire to be used with 100%CO2 gas
shielding. It provide excellent notch toughness at low temperature,
not only as-welded but also stress relieved state
Mechanical Properties
& Chemical Compositions of all-Weld Metal
Welding Conditions
Welding Position : 1G(PA)
Diameter : 1.2mm (0.045in)
Shielding Gas : 100%CO₂
Flow Rate : 20 ℓ /min
Amp./ Volt. : 280A / 32V
Stick-Out : 20~25mm (0.79~0.98in)
Pre-Heat : R.T .
Interpass Temp. : 150±15℃ (302±59℉)
Polarity : DC(+)