Xiang Welding Industrial Co Ltd
AWS A5.5 / ASME SFA5.5 E9015-B9
JIS Z3223 E6215-9C1MV
EN 1599 ECrMo91 B 4 2 H5
Notes on Usage
Welding Positions:
① Dry the electrodes at 350~400℃(662~752℉) for 60 minutes before use.
② Preheat at 200~315℃(400~600℉) and postheat at 750~770℃(1382~1418℉).
③ Adopt back step method or strike the arc on a small steel plate prepared for this particular purpose to prevent blow hole at the arc starting.
Applications
AWS A5.5 / ASME SFA5.5 E9015(6)-G H4 can be used for Welding of 9%Cr-0.5%Mo-1.5%W heat resistant steel. Used for pipes of boilers for power plant, equipment for oil refining industries, and high temperature synthetic chemical industries.
Welding Position
Characteristics on Usage
AWS A5.5 / ASME SFA5.5 E9015(6)-G H4 is low hydrogen type electrode is designed to weld equivalent ‘type 92’ 9CrMoW
steels modified with small additions of niobium, vanadium and nitrogen give improved long term creep properties. Its usability is good with AC/DC+ applications and very low hydrogen electrode.(HDM ≤ 5ml/100g)
Current
AC or DC +
S-9015.B92 (DC+ only)