Xiang Welding Industrial Co Ltd
AWS A5.5 / ASME SFA5.5 E7018-W1
JIS Z3214 DA5026G
EN ISO 2560-A - E42 2 B 3 2
Notes on Usage
Welding Positions:
① Dry the electrodes at 350~400℃(662~752℉) for 60 minutes before use.
② Adopt back step method or strike the arc on a small steel plate prepared for this particular purpose because arc striking on the base metal is in danger of initiating cracking.
③ Preheat at 80~100℃(176~212℉)before use. The temperature to be applied varies in accordance with plate thickness and steel kind.
Applications
AWS A5.5 / ASME SFA5.5 E7018-W1 can be used for welding of carbon and high tensile weather proof steel.
Welding Position
Characteristics on Usage
AWS A5.5 / ASME SFA5.5 E7018-W1 is an iron powder, low hydrogen type electrode for all position welding.
It shows high resistibility to the atmospheric corrosion, since its all weld metal contains Cu, Ni, Cr.
Crack resistibility and mechanical properties are good.
Current
AC or DC +