Xiang Welding Industrial Co Ltd
AWS A5.5 E10018-D2 H4R
Notes on Usage
Welding Positions:
1.Dry the electrodes at 350℃∼400℃(662~752℉) for 60 minutes before use
2. Adopt back step method or strike the arc on a small steel plate prepared for this particular purpose because are striking on the base metal is danger of initiating cracking.
3. If each pass welds becomes thicker than acceptable level by high amperage or low speed ratio application, the impact values and yield points will decrease.
4. Keep the arc as short as possible.
Applications
AWS A5.5 E10018-D2 H4R can be used for welding of carbon-Manganese and Chromium-Molybdenum steels such as process piping (AISI 4130, 4140)
Characteristics on Usage
AWS A5.5 E10018-D2 H4R  is a low hydrogen type electrode for welding 690MPa class
Low alloy steel.
The weld metal has a good crack resistibility.
X-ray performance and usability are good.
Mechanical Properties
& Chemical Compositions of all-Weld Metal
Welding Conditions
Diameter, mm(in) : 4.0 X 400(5/32 X 16)
Amp./ Volt. : 170 / 23~25
Interpass Temp.℃(℉) : 95~110(203~230)
Polarity : DC+