Xiang Welding Industrial Co Ltd
ER309 Stainless steel welding wire is used to weld base metals of similar composition in wrought or cast form. It is also used to weld type 304 and similar base metals where severe conditions may exist. Occasionally, used to weld dissimilar steels.
Stainless Welding Wire 
APPLICATION:
Specification:
Welding Positions:
Typical Applications
Features:
AWS A5.9 ER309
Stainless steel 309 welding wire welds 304 and similar base metals in wrought or cast form where severe corrosion conditions may exist
Sometimes welds dissimilar steels
86,000 psi tensile strength (as welded)
57,000 psi yield strength (as welded)
47% elongation; 68% reduction of area (as welded)
85 HRB Rockwell B hardness (as welded)
160 HB Brinell hardness (as welded)
105 ft./lb. @ room temperature Charpy V (as welded)
Conforms to ANSI/AWS A5.9 & ASME SFA 5.9 ER 309
Benefits of Stainless Steel Wire Drawing
Excellent Surface Finishing
Mass Production Capabilities
Accurate Control for Strict Dimensions
Economical Efficiency
Quick Turnaround
RECOMMENDED WELDING PARAMETERS:
AWS A5.9:                        ER309, ER309L
ASME SFA-A5.9:             ER309, ER309L
ABS:                                 ER309, ER309L
CWB/CSA W48-06:          ER309L
EN ISO 14343-B:             SS309L
ISO 14343:2009:              (23 12 L)
MIL-E-19933E (SH)           MIL 309






• ASTM A743, A744 Types CF-8 and CF-3 and ASTM
A240 Type 309S
• For joining carbon or mild alloy steel to austenitic
stainless steels
• Can also be used on “18-8” steels, since it overmatches the
corrosion resistance, if the weldment will not be exposed to
temperatures of 538° C to 927° C (1000° F to 1700° F)
• Ideal for joining stainless steels to themselves or to carbon orlow alloy steels, and can be used at temperatures up to700°F (371°C)
*GMAW (MIG) Parameters (DC Reverse Polarity) Electrode Positive Short-Circuiting transfer
Wire Diameter            Amps               Volts                90% Helium + 7.5% Argon +            Wire Feed (ipm)
                                                                                              2.5% CO2 (cfh)

.030                           60-125               17-22                             20-25                                             150-430
.035                           75-160               17-22                             20-25                                             120-400
.045                           100-200             17-22                             20-25                                             100-240
*GMAW (MIG) Parameters (DC Reverse Polarity) Electrode Positive Spray transfer
Wire Diameter            Amps              Volts                       Argon / 1-2% O2                         Wire Feed (ipm)
.030                            160-225           24-28                               25                                               440-650
.035                            180-300           24-29                               30                                               430-500
.045                            200-450           24-30                            30-35                                             220-400
1/16                            225-500           24-32                               40                                               110-210
3/32                            250-600           24-32                               50                                                 50-80